Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	45
Date	08/12/14
Start Time	10:52:05
Diameter Midpoint
 10.9	675.681
 11.3	95951.5
 11.8	437994
 12.2	463888
 12.6	500516
 13.1	550723
 13.6	598852
 14.1	642090
 14.6	681226
 15.1	719914
 15.7	751907
 16.3	779112
 16.8	796247
 17.5	802032
 18.1	798675
 18.8	787552
 19.5	767072
 20.2	740786
 20.9	693385
 21.7	652108
 22.5	597232
 23.3	532116
 24.1	463641
 25.0	385848
 25.9	317535
 26.9	251789
 27.9	192098
 28.9	141057
 30.0	101305
 31.1	69732.3
 32.2	47560.8
 33.4	30756.2
 34.6	19917.6
 35.9	12314.8
 37.2	7951.31
 38.5	5010.39
 40.0	3382.25
 41.4	2293.16
 42.9	1695.04
 44.5	1256.91
 46.1	1039
 47.8	797.432
 49.6	772.73
 51.4	537.304
 53.3	517.424
 55.2	348.21
 57.3	328.616
 59.4	294.176
 61.5	300.828
 63.8	191.899
 66.1	207.625
 68.5	176.865
 71.0	133.534
 73.7	171.863
 76.4	125.373
 79.1	87.0709
 82.0	114.903
 85.1	77.5857
 88.2	97.2994
 91.4	70.7231
 94.7	93.5597
 98.2	88.1153
101.8	69.1354
105.5	53.9562
109.4	55.9599
113.4	61.8652
117.6	79.755
121.9	58.4942
126.3	63.6961
131.0	44.9264
135.8	50.9356
140.7	63.2345
145.9	49.95
151.2	38.4916
156.8	36.3031
162.5	41.1387
168.5	56.3469
174.7	33.5507
181.1	30.4237
187.7	28.9365
194.6	39.1509
201.7	42.0737
209.1	37.0926
216.7	33.1458
224.7	20.7067
232.9	36.8733
241.4	24.422
250.3	33.3623
259.5	22.2232
269.0	21.6727
278.8	23.7733
289.0	15.8698
299.6	12.124
310.6	12.4117
322.0	10.2129
333.8	9.07229
346.0	1.49496
358.7	13.0237
371.8	4.41825
385.4	15.6113
399.5	4.6867
414.2	9.2757
429.4	7.09028
445.1	7.18085
461.4	7.32386
478.3	8.91783
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1645
High Voltage	9857.66
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	17.7116
Mean(nm)	18.4118
Geo. Mean(nm)	17.8528
Mode(nm)	17.4658
Geo. Std. Dev.	1.27685
Total Concentration(#/cm)	1.54532e+007
Comment	